Chongqing Ningcai Generate Power Co.,Ltd
|
Payment Terms: | T/T |
Place of Origin: | , China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Rated Output(KW) | 30 |
Standby Output(KW) | 33 |
Voltage(V) | 400 |
Current(A) | 54 |
Size(mm) | 1800*780*1420 |
Approximate weight(KG) | 850 |
Emission levels (Nox) | Euro II emission(mg/m³) |
Naturally aspirated engine intake air temperature | None |
Air temperature before entering the air to air intercooler | 82-87(Deg C) |
Air temperature after entering the air to air intercooler | 35-42(Deg C) |
Rated Power @ 0.8 power factor (w / pump s and w / o fan) | 30KW (continuous operation) |
Total energy input (100% load) | 83(KW) |
Electrical efficiency | 36.20% |
Thermal efficiency | 87.90% |